{{ ansible_header | comment }}
procurve_switch:
walk:
- 1.3.6.1.2.1.31.1.1.1.10
- 1.3.6.1.2.1.31.1.1.1.6
get:
- 1.3.6.1.2.1.1.3.0
- 1.3.6.1.2.1.1.5.0
- 1.3.6.1.2.1.1.6.0
metrics:
- name: procurve_sysUpTime
oid: 1.3.6.1.2.1.1.3
type: gauge
help: The time (in hundredths of a second) since the network management portion
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
- name: procurve_sysName
oid: 1.3.6.1.2.1.1.5
type: DisplayString
help: An administratively-assigned name for this managed node - 1.3.6.1.2.1.1.5
- name: procurve_sysLocation
oid: 1.3.6.1.2.1.1.6
type: DisplayString
help: The physical location of this node (e.g., 'telephone closet, 3rd floor')
- 1.3.6.1.2.1.1.6
- name: procurve_ifHCOutOctets
oid: 1.3.6.1.2.1.31.1.1.1.10
type: counter
help: The total number of octets transmitted out of the interface, including framing
characters - 1.3.6.1.2.1.31.1.1.1.10
indexes:
- labelname: ifIndex
type: gauge
- name: procurve_ifHCInOctets
oid: 1.3.6.1.2.1.31.1.1.1.6
type: counter
help: The total number of octets received on the interface, including framing
characters - 1.3.6.1.2.1.31.1.1.1.6
indexes:
- labelname: ifIndex
type: gauge
version: 3
auth:
# To create SNMPv3 user on HP procurve, execute:
# snmpv3 user snmp_prometheus auth sha {{ snmp_exporter.procurve_password }} priv aes {{ snmp_exporter.procurve_password }}
# snmpv3 group managerpriv user snmp_prometheus sec-model ver3
security_level: authPriv
username: snmp_prometheus
password: {{ snmp_exporter.procurve_password }}
auth_protocol: SHA
priv_protocol: AES
priv_password: {{ snmp_exporter.procurve_password }}
ilo:
walk:
- 1.3.6.1.4.1.232.6.2.14.4 # Resilient memory
- 1.3.6.1.4.1.232.6.2.15.3 # Power meter
- 1.3.6.1.4.1.232.6.2.16.1 # POST tests
- 1.3.6.1.4.1.232.6.2.17.1 # Battery
- 1.3.6.1.4.1.232.6.2.6.8.1.3 # Temperature sensors location
- 1.3.6.1.4.1.232.6.2.6.8.1.4 # Temperature sensors value
- 1.3.6.1.4.1.232.6.2.6.8.1.5 # Temperature sensors limit
- 1.3.6.1.4.1.232.6.2.6.8.1.6 # Temperature sensors condition
- 1.3.6.1.4.1.232.6.2.6.7.1.3 # Fans location
- 1.3.6.1.4.1.232.6.2.6.7.1.9 # Fans condition
- 1.3.6.1.4.1.232.6.2.9.3.1.5 # Power supply
- 1.3.6.1.4.1.232.9.2.2 # iLO
metrics:
- name: cpqHeResilientMemCondition
oid: 1.3.6.1.4.1.232.6.2.14.4
type: EnumAsStateSet
help: The resilient memory condition - 1.3.6.1.4.1.232.6.2.14.4
enum_values:
1: other
2: ok
3: degraded
4: failed
- name: cpqHePowerMeterCurrReading
oid: 1.3.6.1.4.1.232.6.2.15.3
type: gauge
help: This is the current Power Meter reading in Watts - 1.3.6.1.4.1.232.6.2.15.3
- name: cpqHeHWBiosCondition
oid: 1.3.6.1.4.1.232.6.2.16.1
type: EnumAsStateSet
help: This value indicates an error has been detected during Pre-OS Test (POST)
or during initial hardware initialization - 1.3.6.1.4.1.232.6.2.16.1
enum_values:
1: other
2: ok
3: degraded
4: failed
- name: cpqHeSysBatteryCondition
oid: 1.3.6.1.4.1.232.6.2.17.1
type: EnumAsStateSet
help: The battery condition - 1.3.6.1.4.1.232.6.2.17.1
indexes:
- labelname: cpqHeSysBatteryChassis
type: gauge
- labelname: cpqHeSysBatteryIndex
type: gauge
enum_values:
1: other
2: ok
3: degraded
4: failed
- name: cpqHeTemperatureLocale
oid: 1.3.6.1.4.1.232.6.2.6.8.1.3
type: EnumAsInfo
help: This specifies the location of the temperature sensor present in the system.
- 1.3.6.1.4.1.232.6.2.6.8.1.3
indexes:
- labelname: cpqHeTemperatureChassis
type: gauge
- labelname: cpqHeTemperatureIndex
type: gauge
enum_values:
1: other
2: unknown
3: system
4: systemBoard
5: ioBoard
6: cpu
7: memory
8: storage
9: removableMedia
10: powerSupply
11: ambient
12: chassis
13: bridgeCard
- name: cpqHeTemperatureCelsius
oid: 1.3.6.1.4.1.232.6.2.6.8.1.4
type: gauge
help: This is the current temperature sensor reading in degrees celsius - 1.3.6.1.4.1.232.6.2.6.8.1.4
indexes:
- labelname: cpqHeTemperatureChassis
type: gauge
- labelname: cpqHeTemperatureIndex
type: gauge
- name: cpqHeTemperatureThreshold
oid: 1.3.6.1.4.1.232.6.2.6.8.1.5
type: gauge
help: This is the shutdown threshold temperature sensor setting in degrees celsius
- 1.3.6.1.4.1.232.6.2.6.8.1.5
indexes:
- labelname: cpqHeTemperatureChassis
type: gauge
- labelname: cpqHeTemperatureIndex
type: gauge
- name: cpqHeTemperatureCondition
oid: 1.3.6.1.4.1.232.6.2.6.8.1.6
type: EnumAsStateSet
help: The Temperature sensor condition - 1.3.6.1.4.1.232.6.2.6.8.1.6
indexes:
- labelname: cpqHeTemperatureChassis
type: gauge
- labelname: cpqHeTemperatureIndex
type: gauge
enum_values:
1: other
2: ok
3: degraded
4: failed
- name: cpqHeFltTolFanLocale
oid: 1.3.6.1.4.1.232.6.2.6.7.1.3
type: EnumAsInfo
help: This specifies the location of the fan present in the system.
- 1.3.6.1.4.1.232.6.2.6.7.1.3
indexes:
- labelname: cpqHeFltTolFanChassis
type: gauge
- labelname: cpqHeFltTolFanIndex
type: gauge
enum_values:
1: other
2: unknown
3: system
4: systemBoard
5: ioBoard
6: cpu
7: memory
8: storage
9: removableMedia
10: powerSupply
11: ambient
12: chassis
13: bridgeCard
- name: cpqHeFltTolFanCondition
oid: 1.3.6.1.4.1.232.6.2.6.7.1.9
type: EnumAsStateSet
help: The fan condition - 1.3.6.1.4.1.232.6.2.6.7.1.9
indexes:
- labelname: cpqHeFltTolFanChassis
type: gauge
- labelname: cpqHeFltTolFanIndex
type: gauge
enum_values:
1: other
2: ok
3: degraded
4: failed
- name: cpqHeFltTolPowerSupplyStatus
oid: 1.3.6.1.4.1.232.6.2.9.3.1.5
type: EnumAsStateSet
help: The status of the power supply. - 1.3.6.1.4.1.232.6.2.9.3.1.5
indexes:
- labelname: cpqHeFltTolPowerSupplyChassis
type: gauge
- labelname: cpqHeFltTolPowerSupplyBay
type: gauge
enum_values:
1: noError
2: generalFailure
3: bistFailure
4: fanFailure
5: tempFailure
6: interlockOpen
7: epromFailed
8: vrefFailed
9: dacFailed
10: ramTestFailed
11: voltageChannelFailed
12: orringdiodeFailed
13: brownOut
14: giveupOnStartup
15: nvramInvalid
16: calibrationTableInvalid
17: noPowerInput
- name: cpqSm2CntlrInterfaceStatus
oid: 1.3.6.1.4.1.232.9.2.2.17
type: EnumAsStateSet
help: Remote Insight/ Integrated Lights-Out Interface Status - 1.3.6.1.4.1.232.9.2.2.17
enum_values:
1: other
2: ok
3: notResponding
- name: cpqSm2CntlriLOSecurityOverrideSwitchState
oid: 1.3.6.1.4.1.232.9.2.2.27
type: EnumAsStateSet
help: Integrated Lights-Out Security Override Switch State - 1.3.6.1.4.1.232.9.2.2.27
enum_values:
1: notSupported
2: set
3: notSet
- name: cpqSm2CntlrLicenseActive
oid: 1.3.6.1.4.1.232.9.2.2.30
type: EnumAsStateSet
help: Remote Insight License State - 1.3.6.1.4.1.232.9.2.2.30
enum_values:
1: none
2: iloAdvanced
3: iloLight
4: iloAdvancedBlade
5: iloStandard
6: iloEssentials
7: iloScaleOut
8: iloAdvancedPremiumSecurity
- name: cpqSm2CntlrServerPowerState
oid: 1.3.6.1.4.1.232.9.2.2.32
type: EnumAsStateSet
help: The current power state for the server - 1.3.6.1.4.1.232.9.2.2.32
enum_values:
1: unknown
2: poweredOff
3: poweredOn
4: insufficientPowerOrPowerOnDenied
version: 3
# Reduce timeout to retry faster
timeout: 1s
auth:
security_level: authPriv
username: crans
password: SpnVOv4nuF10BOye9zjX
auth_protocol: SHA
priv_protocol: AES
priv_password: 21rW6LHShmgdHsdPQXHP
apc:
walk:
- 1.3.6.1.4.1.318.1.1.12.2.3.1.1.2
- 1.3.6.1.4.1.318.1.1.12.3.5.1.1.7
- 1.3.6.1.4.1.318.1.1.26.9.4.3.1.11
- 1.3.6.1.4.1.318.1.1.26.9.4.3.1.6
- 1.3.6.1.4.1.318.1.1.26.9.4.3.1.7
get:
- 1.3.6.1.4.1.318.1.1.12.1.16.0
metrics:
- name: rPDUIdentDevicePowerWatts
oid: 1.3.6.1.4.1.318.1.1.12.1.16
type: gauge
help: Getting this OID will return the Power in Watts. - 1.3.6.1.4.1.318.1.1.12.1.16
- name: rPDULoadStatusLoad
oid: 1.3.6.1.4.1.318.1.1.12.2.3.1.1.2
type: gauge
help: Getting this OID will return the phase/bank load measured in tenths of Amps.
- 1.3.6.1.4.1.318.1.1.12.2.3.1.1.2
indexes:
- labelname: rPDULoadStatusIndex
type: gauge
- name: rPDUOutletStatusLoad
oid: 1.3.6.1.4.1.318.1.1.12.3.5.1.1.7
type: gauge
help: Getting this OID will return the measured Outlet load for an Outlet Monitored
Rack PDU in tenths of Amps - 1.3.6.1.4.1.318.1.1.12.3.5.1.1.7
indexes:
- labelname: rPDUOutletStatusIndex
type: gauge
- name: rPDU2OutletMeteredStatusEnergy
oid: 1.3.6.1.4.1.318.1.1.26.9.4.3.1.11
type: gauge
help: A user resettable energy meter measuring Rack PDU load energy consumption
in tenths of kilowatt-hours - 1.3.6.1.4.1.318.1.1.26.9.4.3.1.11
indexes:
- labelname: rPDU2OutletMeteredStatusIndex
type: gauge
- name: rPDU2OutletMeteredStatusCurrent
oid: 1.3.6.1.4.1.318.1.1.26.9.4.3.1.6
type: gauge
help: Indicates the current draw, in tenths of Amps, of the load on the Rack PDU
outlet being queried - 1.3.6.1.4.1.318.1.1.26.9.4.3.1.6
indexes:
- labelname: rPDU2OutletMeteredStatusIndex
type: gauge
- name: rPDU2OutletMeteredStatusPower
oid: 1.3.6.1.4.1.318.1.1.26.9.4.3.1.7
type: gauge
help: Indicates the power draw of the load on the Rack PDU outlet being queried
- 1.3.6.1.4.1.318.1.1.26.9.4.3.1.7
indexes:
- labelname: rPDU2OutletMeteredStatusIndex
type: gauge
auth:
username: crans
printer_mib:
walk:
- 1.3.6.1.2.1.25.3.5.1.1
- 1.3.6.1.2.1.43.11.1.1.5
- 1.3.6.1.2.1.43.11.1.1.6
- 1.3.6.1.2.1.43.11.1.1.8
- 1.3.6.1.2.1.43.11.1.1.9
- 1.3.6.1.2.1.43.5.1.1.13
- 1.3.6.1.2.1.43.5.1.1.16
- 1.3.6.1.2.1.43.5.1.1.17
- 1.3.6.1.2.1.43.5.1.1.18
- 1.3.6.1.2.1.43.5.1.1.19
- 1.3.6.1.2.1.43.5.1.1.3
- 1.3.6.1.2.1.43.6.1.1.3
- 1.3.6.1.4.1.641.1.0.2
- 1.3.6.1.4.1.641.1.0.3
- 1.3.6.1.4.1.641.1.0.4
- 1.3.6.1.4.1.641.1.0.5
- 1.3.6.1.4.1.641.1.0.8
- 1.3.6.1.4.1.641.2.1.3.1.3
- 1.3.6.1.4.1.641.2.1.3.1.4
- 1.3.6.1.4.1.641.2.1.3.1.5
- 1.3.6.1.4.1.641.2.1.3.1.6
- 1.3.6.1.4.1.641.2.1.3.1.7
- 1.3.6.1.4.1.641.2.1.3.1.8
- 1.3.6.1.4.1.641.2.1.3.1.9
- 1.3.6.1.4.1.641.6.4.2.3.1.3
- 1.3.6.1.4.1.641.6.5.1.1.4
- 1.3.6.1.4.1.641.6.5.1.1.5
- 1.3.6.1.4.1.641.6.5.1.1.6
get:
- 1.3.6.1.2.1.1.3.0
- 1.3.6.1.4.1.641.2.1.5.1.0
- 1.3.6.1.4.1.641.2.1.5.2.0
- 1.3.6.1.4.1.641.2.1.5.3.0
metrics:
- name: sysUpTime
oid: 1.3.6.1.2.1.1.3
type: gauge
help: The time (in hundredths of a second) since the network management portion
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
- name: hrPrinterStatus
oid: 1.3.6.1.2.1.25.3.5.1.1
type: EnumAsStateSet
help: The current status of this printer device. - 1.3.6.1.2.1.25.3.5.1.1
indexes:
- labelname: hrDeviceIndex
type: gauge
enum_values:
1: other
2: unknown
3: idle
4: printing
5: warmup
- name: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
help: The type of this supply. - 1.3.6.1.2.1.43.11.1.1.5
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
enum_values:
1: other
2: unknown
3: toner
4: wasteToner
5: ink
6: inkCartridge
7: inkRibbon
8: wasteInk
9: opc
10: developer
11: fuserOil
12: solidWax
13: ribbonWax
14: wasteWax
15: fuser
16: coronaWire
17: fuserOilWick
18: cleanerUnit
19: fuserCleaningPad
20: transferUnit
21: tonerCartridge
22: fuserOiler
23: water
24: wasteWater
25: glueWaterAdditive
26: wastePaper
27: bindingSupply
28: bandingSupply
29: stitchingWire
30: shrinkWrap
31: paperWrap
32: staples
33: inserts
34: covers
35: matteToner
36: matteInk
- name: prtMarkerSuppliesDescription
oid: 1.3.6.1.2.1.43.11.1.1.6
type: DisplayString
help: The description of this supply container/receptacle in the localization
specified by prtGeneralCurrentLocalization. - 1.3.6.1.2.1.43.11.1.1.6
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
- name: prtMarkerSuppliesMaxCapacity
oid: 1.3.6.1.2.1.43.11.1.1.8
type: gauge
help: The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit
- 1.3.6.1.2.1.43.11.1.1.8
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
- name: prtMarkerSuppliesLevel
oid: 1.3.6.1.2.1.43.11.1.1.9
type: gauge
help: The current level if this supply is a container; the remaining space if
this supply is a receptacle - 1.3.6.1.2.1.43.11.1.1.9
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
- name: prtConsoleDisable
oid: 1.3.6.1.2.1.43.5.1.1.13
type: EnumAsStateSet
help: This value indicates how input is (or is not) accepted from the operator
console - 1.3.6.1.2.1.43.5.1.1.13
indexes:
- labelname: hrDeviceIndex
type: gauge
enum_values:
3: enabled
4: disabled
- name: prtGeneralPrinterName
oid: 1.3.6.1.2.1.43.5.1.1.16
type: DisplayString
help: An administrator-specified name for this printer - 1.3.6.1.2.1.43.5.1.1.16
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtGeneralSerialNumber
oid: 1.3.6.1.2.1.43.5.1.1.17
type: DisplayString
help: A recorded serial number for this device that indexes some type device catalog
or inventory - 1.3.6.1.2.1.43.5.1.1.17
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtAlertCriticalEvents
oid: 1.3.6.1.2.1.43.5.1.1.18
type: counter
help: A running counter of the number of critical alert events that have been
recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.18
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtAlertAllEvents
oid: 1.3.6.1.2.1.43.5.1.1.19
type: counter
help: A running counter of the total number of alert event entries (critical and
non-critical) that have been recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.19
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtGeneralReset
oid: 1.3.6.1.2.1.43.5.1.1.3
type: EnumAsStateSet
help: Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults'
will result in the resetting of the printer - 1.3.6.1.2.1.43.5.1.1.3
indexes:
- labelname: hrDeviceIndex
type: gauge
enum_values:
3: notResetting
4: powerCycleReset
5: resetToNVRAM
6: resetToFactoryDefaults
- name: prtCoverStatus
oid: 1.3.6.1.2.1.43.6.1.1.3
type: EnumAsStateSet
help: The status of this cover sub-unit. - 1.3.6.1.2.1.43.6.1.1.3
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtCoverIndex
type: gauge
enum_values:
1: other
2: unknown
3: coverOpen
4: coverClosed
5: interlockOpen
6: interlockClosed
- name: prtgenStatusOutHopFull
oid: 1.3.6.1.4.1.641.2.1.3.1.3
type: gauge
help: The printer's current output hopper status. - 1.3.6.1.4.1.641.2.1.3.1.3
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: notFull
2: full
3: unknown
- name: prtgenStatusInputEmpty
oid: 1.3.6.1.4.1.641.2.1.3.1.4
type: gauge
help: The printer's current active input paper tray status. - 1.3.6.1.4.1.641.2.1.3.1.4
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: notEmpty
2: empty
3: unknown
- name: prtgenStatusPaperJam
oid: 1.3.6.1.4.1.641.2.1.3.1.5
type: gauge
help: The printer's current paper path status. - 1.3.6.1.4.1.641.2.1.3.1.5
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: notJammed
2: jamed
3: unknown
- name: prtgenStatusTonerError
oid: 1.3.6.1.4.1.641.2.1.3.1.6
type: gauge
help: The printer's current toner supply status. - 1.3.6.1.4.1.641.2.1.3.1.6
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: noTonerError
2: tonerError
3: unknown
- name: prtgenStatusSrvcReqd
oid: 1.3.6.1.4.1.641.2.1.3.1.7
type: gauge
help: The printer's current service required status. - 1.3.6.1.4.1.641.2.1.3.1.7
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: noServiceRequired
2: serviceRequired
3: unknown
- name: prtgenStatusDiskError
oid: 1.3.6.1.4.1.641.2.1.3.1.8
type: gauge
help: The printer's current disk sub-system status. - 1.3.6.1.4.1.641.2.1.3.1.8
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: noDiskError
2: diskError
3: unknown
- name: prtgenStatusCoverOpen
oid: 1.3.6.1.4.1.641.2.1.3.1.9
type: gauge
help: The printer's current cover status. - 1.3.6.1.4.1.641.2.1.3.1.9
indexes:
- labelname: prtgenStatPrinterIndex
type: gauge
enum_values:
1: noCoverOpen
2: coverOpen
3: unknown
- name: pgTotal
oid: 1.3.6.1.4.1.641.2.1.5.1
type: counter
help: The total number of pages printed. - 1.3.6.1.4.1.641.2.1.5.1
- name: pgMono
oid: 1.3.6.1.4.1.641.2.1.5.2
type: counter
help: The number of monochrome pages printed. - 1.3.6.1.4.1.641.2.1.5.2
- name: pgColor
oid: 1.3.6.1.4.1.641.2.1.5.3
type: counter
help: The number of color pages printed. - 1.3.6.1.4.1.641.2.1.5.3
- name: paperSheetsPaperType
oid: 1.3.6.1.4.1.641.6.4.2.3.1.3
type: gauge
help: The type of the paper - 1.3.6.1.4.1.641.6.4.2.3.1.3
indexes:
- labelname: deviceIndex
type: gauge
- labelname: paperSheetsCountIndex
type: gauge
enum_values:
1: unknown
2: other
3: plain
4: cardstock
5: transparancy
6: recycled
7: labels
8: vinylLabels
9: bond
10: letterhead
11: preprinted
12: colored
13: light
14: heavy
15: roughOrCotton
16: envelope
17: premimuPlain
18: colorLokCertifiedPlain
19: lexmarkPerfectFinishPhoto
20: lexmarkPhoto
21: glossyPhoto
22: mattePhoto
23: inkjetMatteBrochure
24: inkjetGlossyBrochure
25: ironOnTransfer
32: customtype1
33: customtype2
34: customtype3
35: customtype4
36: customtype5
37: customtype6
38: coatedPaper
39: glossy
40: photPaper
41: greetingCard
42: heavyCard
43: roughEnvelop
44: heavyCottonPaper
45: veryHeavyPaper
46: heavyGloss
47: rfidLabels
48: businessCard
- name: deviceAlertSeverity
oid: 1.3.6.1.4.1.641.6.5.1.1.4
type: gauge
help: The severity of this alert - 1.3.6.1.4.1.641.6.5.1.1.4
indexes:
- labelname: deviceIndex
type: gauge
- labelname: deviceAlertIndex
type: gauge
enum_values:
1: unknown
2: other
3: informational
4: warning
5: critical
6: serviceRequired
- name: deviceAlertCode
oid: 1.3.6.1.4.1.641.6.5.1.1.5
type: gauge
help: An alert code to indicate what type of alert condition this row refers to
- 1.3.6.1.4.1.641.6.5.1.1.5
indexes:
- labelname: deviceIndex
type: gauge
- labelname: deviceAlertIndex
type: gauge
enum_values:
1: unknown
2: other
3: coverOpen
4: coverClosed
5: interlockOpen
6: interlockClosed
7: doorOpen
8: doorClosed
9: calibrating
10: alignmentFailed
11: warrantyOverrideRequired
12: printHeadCarrierPathObstructed
13: heldJobsMayNotBeRestored
14: busy
15: waiting
100: subunitErrorOther
101: subunitLifeAlmostOver
102: subunitLifeOver
103: subunitJammed
104: subunitUnderTemperature
105: subunitOverTemperature
106: subunitInsufficientMemory
107: subunitMemoryFull
108: subunitNVFailure
109: subunitDisabled
110: subunitCommunicationError
200: supplyErrorOther
201: supplyOk
202: supplyEarlyWarning
203: supplyNearFull
205: supplyFull
206: supplyNearLow
207: supplyLow
208: supplyNearEmpty
209: supplyEmpty
210: supplyLifeAlmostOver
211: supplyLifeOver
212: supplyNearReplace
213: supplyReplace
214: supplyMissing
215: supplyInvalid
216: supplyDefective
217: supplyImproperInstall
218: supplyUnsupported
219: supplyUncalibrated
300: inputMediaErrorOther
301: inputMediaTrayMissing
302: inputMediaSupplyLow
303: inputMediaSupplyEmpty
304: inputMediaChangeRequest
305: inputMediaLoadRequest
400: outputMediaErrorOther
401: outputMediaTrayMissing
402: outputMediaNearFull
403: outputMediaFull
404: outputMediaEmptyRequest
500: mediaPathErrorOther
501: mediaPathPaperJam
600: scannerErrorOther
601: scannerLampWarming
602: scannerLampLifeWarning
603: scannerLampError
604: scannerADFJam
605: scannerStalled
606: scannerLocked
607: scannerDisabled
700: faxErrorOther
701: faxStorageNearFull
702: faxStorageFull
703: faxStorageSendNearFull
704: faxStorageSendFull
705: faxStorageReceiveNearFull
706: faxStorageReceiveFull
707: faxPhoneLineDisconnected
708: faxDisabled
709: faxConfigurationError
800: interpreterErrorOther
801: interpreterInsufficientMemory
802: interpreterOutOfMemory
803: interpreterComplexPage
804: interpreterJobHardwareMismatch
805: interpreterPrintDataExceedsMediaSize
900: emailErrorOther
901: emailConfigurationError
1000: storageErrorOther
1001: storageUnformatted
1002: storageFull
20000: neverError
- name: deviceAlertDescription
oid: 1.3.6.1.4.1.641.6.5.1.1.6
type: DisplayString
help: A description of the alert condition - 1.3.6.1.4.1.641.6.5.1.1.6
indexes:
- labelname: deviceIndex
type: gauge
- labelname: deviceAlertIndex
type: gauge